Item |
Description |
√ |
Add detergent |
Add ATF detergent to AT |
√ |
Exchange |
Exchanging ATF |
√ |
Adjust fluid level |
Adjusting the quantity of fluid inside AT |
√ |
Empty new tank |
Draining left fluid inside new fluid tank |
√ |
Empty used tank |
Draining used fluid inside used fluid tank |
√ |
System setting |
Calibration of electronic, scale, adjusting contrast, language selection, and database entry. |
√ |
Power supply
|
AC110V/220V 50Hz/60Hz
|
150W pump power
|
150W
|
Working temperature
|
-10~50℃
|
Relative humidity
|
<90%
|
Working noise
|
<70db
|
Working air pressure
|
86~106kpa
|
Waterproof and dustproof
|
Ip42
|
Filter accuracy
|
5μm
|
Rate of flow
|
≥2.2L/60s
|
Oil Tank
|
20L×2
|
Equal exchange error
|
±100mli
|
Pay attention to each connection to check if there is any leakage during fluid exchange. When any leak is found, stop the CAT-501S immediately and check for the unit.
Start to exchange fluid again after reconnection is made.
Before cleaning up the unit, the used fluid should be drained out from the used fluid tank and the new fluid should be drained out from new tank and stored in container after every usage to protect the electronic scale is on the no load state at non-work condition.
Keep the new fluid tank clean.
Please recalibrate the electronic scale after replacing the main-board and/or the electronic scale itself.